The Electrical Code Regulation now adopts the following two codes: CSA- C22.1-18 – Canadian Electrical Code, Part I (twenty-fourth edition) – This code provides the minimum safety standards for the installation and maintenance of electrical equipment. Alberta Electrical Utility Code – 5th Edition, 2016 – This code provides the minimum.
2018 Canadian Electrical Code, Part I (24th edition), Safety Standard for Electrical Installations
![Electrical Electrical](/uploads/1/2/6/3/126315273/718989512.jpg)
Preface
This twenty-fourth edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2017 meetings in Halifax, Nova Scotia. This twenty-fourth edition supersedes the previous editions, published in 2015, 2012, 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927.This edition features important revisions to many Sections. Section 26 now mandates the use of tamper-resistant receptacles in additional areas where children may be present. Section 62 now requires ground fault circuit interrupter protection for heating devices and controls in proximity to tubs, sinks, and shower stalls.
Section 10 has been updated, reorganized, and significantly reduced in length. Requirements for power over ethernet systems have been added to Section 16, and requirements for marinas, wharves, and similar facilities have been substantially updated and reorganized in Section 78.
To address the increasing use of electric vehicles, Section 8 now formally recognizes energy management systems as a method of reducing the load on building services. Because lighting control devices associated with energy management or home automation require power to operate, Section 4 now requires that an identified conductor be provided for all devices controlling permanently installed luminaires.
Other revisions in this edition include the following:
ò in Section 26, Rules 26-400 to 26-726 have been reorganized and renumbered in order to group related concepts together and provide a more logical flow for the requirements;
ò in many Sections, the redundant use of the term ôapprovedö has been eliminated;
ò clarification has been provided on arc-fault circuit interrupter protection for bathrooms, washrooms, existing circuits, and circuits supplying carbon monoxide or smoke alarms;
ò requirements for dining area and refrigerator circuits have been clarified;
ò The terms ôjacketedö, ôinsulatedö, and ôcoveredö as applied to conductors have been clarified through a new definition of the term ôjacketö and a revised definition of the term ôconductorö in Section 0. As a result, the term ôconductorö has been replaced with ôinsulated conductorö in many Sections of the Code; and
ò Section 82 has been deleted as it covered a technology that is no longer in use.
Many of the changes in this edition were developed by cross-functional working groups. Their work is gratefully acknowledged.
General arrangement
The Code is divided into numbered Sections, each covering some main division of the work. Sections 0 to 16 and 26 are considered general sections, and the other sections supplement or amend the general sections. The Sections are divided into numbered Rules, with captions for easy reference, as follows:- Numbering system - With the exception of Section 38, even numbers have been used throughout to identify Sections and Rules. Rule numbers consist of the Section number separated by a hyphen from the 3- or 4-digit figure. The intention in general is that odd numbers may be used for new Rules required by interim revisions. Due to the introduction of some new Rules and the deletion of some existing Rules during the revision of each edition, the Rule numbers for any particular requirement are not always the same in successive editions.
- Subdivision of Rules - Rules are subdivided in the manner illustrated by Rules 8-204 and 8-206, and the subdivisions are identified as follows:
00-000 | Rule
(1) | Subrule
(a) | Item
(i) | item
(A) | item - Reference to other Rules, etc. - Where reference is made to two or more Rules (e.g., Rules 10-200 to 10-206), the first and last Rules mentioned are included in the reference. Where reference is made to a Subrule or Item in the same Rule, only the Subrule number and/or Item letter and the word ôSubruleö or ôItemö need be mentioned. If the reference is to another Rule or Section, then the Rule number and the word ôRuleö shall be stated (e.g., ôRule 10-200(3)ö and not ôSubrule (3) of Rule 10-200ö).
This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.
Scope
This Code applies to all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions:a) installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose;
b) equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power;
c) installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations;
d) aircraft; and
e) electrical systems in ships that are regulated under Transport Canada.
For mines and quarry applications, see also CSA M421.
This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.
Content Provider
CSA America, Inc. [CSA]
Please first log in with a verified email before subscribing to alerts. CSA America, Inc. [CSA]
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
Please first verify your email before subscribing to alerts. Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
Already Subscribed to this document. Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
Documents sold on the ANSI Webstore are in electronic Adobe Acrobat PDF format, however some ISO and IEC standards are available from Amazon in hard copy format.
Some PDF files are protected by Digital Rights Management (DRM) at the request of the copyright holder. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Some copyright holders may impose other restrictions that limit document printing and copy/paste of documents.
Those documents cannot be printed at the request of the copyright holder.
C22.1-12 PACKAGE - Consists of C22.1-12, Canadian electrical code, part I (22nd edition), safety standard for electrical installations; CE code pocket reference book and the C22.1HB-12, CE code handbook, an explanation of rules of the canadian electrical code, part IC22.1-12 - Canadian electrical code, part I (22nd edition), safety standard for electrical installations
Preface
This twenty-second edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2011 meetings in Victoria, British Columbia. This twenty-second edition supersedes the previous editions, published in 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927.
This twenty-second edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2011 meetings in Victoria, British Columbia. This twenty-second edition supersedes the previous editions, published in 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927.
A new Section 64 was added to cover requirements for renewable energy systems and major updates have been made to Section 50 'Solar photovoltaic systems'. Several new conductor types and wiring methods have been recognized and there are significant changes in the Rules and Tables governing ampacity calculations. Grounding and bonding requirements have been revised and new requirements have been added for tamper resistant receptacles and receptacles exposed to the weather. In several sections, rules were added or revised to recognize electric vehicle charging infrastructure. Substantial changes have also been made to requirements for hazardous locations and electric heating.
General arrangement
The Code is divided into numbered Sections, each covering some main division of the work. Sections 0 to 16 and 26 are considered general sections, and the other sections supplement or amend the general sections. The Sections are divided into numbered Rules, with captions for easy reference, as follows:
- Numbering system – With the exception of Section 38, even numbers have been used throughout to identify Sections and Rules. Rule numbers consist of the Section number separated by a hyphen from the 3- or 4-digit figure. The intention in general is that odd numbers may be used for new Rules required by interim revisions. Due to the introduction of some new Rules and the deletion of some existing Rules during the revision of each edition, the Rule numbers for any particular requirement are not always the same in successive editions.
- Subdivision of Rules – Rules are subdivided in the manner illustrated by Rules 8-204 and 8-206, and the subdivisions are identified as follows:
- Reference to other Rules, etc. – Where reference is made to two or more Rules (e.g., Rules 10-200 to 10-206), the first and last Rules mentioned are included in the reference. Where reference is made to a Subrule or Item in the same Rule, only the Subrule number and/or Item letter and the word 'Subrule' or 'Item' need be mentioned. If the reference is to another Rule or Section, then the Rule number and the word 'Rule' shall be stated (e.g., 'Rule 10-200(3)' and not 'Subrule (3) of Rule 10-200').
The principal changes that have been made between the 2009 edition of the Canadian Electrical Code, Part I, and this new edition published in 2012 are marked in the text of the Code by the symbol delta (Δ) in the margin. Where revisions to or deletions from the text have caused existing Rules to be renumbered, only the first renumbered Rule in the sequence is marked. Users of the Code are advised that the change markers in the text are not intended to be all-inclusive and are provided as a convenience only; such markers cannot constitute a comprehensive guide to the reorganization or revision of the Code. Care must therefore be taken not to rely on the change markers to determine the current requirements of the Code. As always, users of the Code must consider the entire Code and any local amendments.
Scope
This Code covers all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions:
This Code covers all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions:
a. installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose
b. equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power
c. installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations
d. aircraft
e. electrical systems in ships that are regulated under Transport Canada.
For mines and quarry applications, see also CSA M421.
This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.
C22.1HB-12 - CE code handbook, an explanation of rules of the canadian electrical code, part 1
This Handbook provides background information on the reasons behind the requirements in the Canadian Electrical Code, Part I, and gives an explanation of each Rule in plain, easy-to-understand language. The Handbook is intended to provide a clearer understanding of the safety requirements of the Code.
The content of this Handbook is not meant to form a code of mandatory requirements. The mandatory language ('shall') that is used in the CE Code, Part I, has not been used here. Care has been taken to ensure that the intent of the Code Rules is clear to the users of the Handbook. However, users of the Handbook must not under any circumstances rely on it to determine the current requirements of the Code. As always, reference must be made to the Code itself and any local amendments. CSA does not assume responsibility for any errors or omissions resulting from the information contained in this Handbook.
The Rules in the CE Code, Part I, are divided into two groups. Sections 0 to 16 and 26 are considered General Sections, and the other Sections supplement or amend those General Sections. Therefore a requirement in the supplementary Sections takes precedence over a general requirement. For example,
b. equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power
c. installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations
d. aircraft
e. electrical systems in ships that are regulated under Transport Canada.
For mines and quarry applications, see also CSA M421.
This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.
C22.1HB-12 - CE code handbook, an explanation of rules of the canadian electrical code, part 1
This Handbook provides background information on the reasons behind the requirements in the Canadian Electrical Code, Part I, and gives an explanation of each Rule in plain, easy-to-understand language. The Handbook is intended to provide a clearer understanding of the safety requirements of the Code.
The content of this Handbook is not meant to form a code of mandatory requirements. The mandatory language ('shall') that is used in the CE Code, Part I, has not been used here. Care has been taken to ensure that the intent of the Code Rules is clear to the users of the Handbook. However, users of the Handbook must not under any circumstances rely on it to determine the current requirements of the Code. As always, reference must be made to the Code itself and any local amendments. CSA does not assume responsibility for any errors or omissions resulting from the information contained in this Handbook.
The Rules in the CE Code, Part I, are divided into two groups. Sections 0 to 16 and 26 are considered General Sections, and the other Sections supplement or amend those General Sections. Therefore a requirement in the supplementary Sections takes precedence over a general requirement. For example,
- Rule 12-1008 requires three threads to be engaged when making a threaded connection, whereas Rule 18-106 requires five threads to be engaged when making a threaded connection in a Class I, Zone 1 area.
- Section 4 permits the use of aluminum conductors, but Rule 32-100 does not allow aluminum conductors to be used in fire alarm systems.
How to buy
Most books are sold and mailed direct to the customer, by airmail where appropriate. Payments can be accepted by check (or bank draft) in Brazilian Real (BRL) or US Dollars. Please email for details.
Please ask for a confirmation of the amount required by email before sending any payment, by contacting [email protected]
For bulk orders and any further questions please email us.
- Section 4 permits the use of aluminum conductors, but Rule 32-100 does not allow aluminum conductors to be used in fire alarm systems.
How to buy
Most books are sold and mailed direct to the customer, by airmail where appropriate. Payments can be accepted by check (or bank draft) in Brazilian Real (BRL) or US Dollars. Please email for details.
Please ask for a confirmation of the amount required by email before sending any payment, by contacting [email protected]
For bulk orders and any further questions please email us.